ELPEPTA RESEARCH LIBRARY
How to Read a Peptide HPLC-MS COA
Published · 2 min read
Read an analytical certificate by matching the sample first, then identifying the question answered by each method. A high purity percentage is only one part of a material record.
What the HPLC result tells you
HPLC separates components before a detector measures their signals. An area percentage describes the assigned peak relative to the peaks included in the integration. It is not automatically a mass fraction. Wavelength, separation and integration affect what the number represents. Bachem’s analytical FAQs (opens in a new tab) explain the interpretation.
Record the detector, method and integration basis alongside the result. Avoid copying a percentage into a summary without its units and context. A chromatogram does not, by itself, answer every question about a material.
How to interpret identity evidence
Mass spectrometry measures ions by mass-to-charge ratio. Charge states and adducts can produce several signals for the same compound. Interpret the spectrum using the stated mass convention and assignments, rather than assuming every peak is a neutral molecular mass. See the Waters mass-spectrometry primer (opens in a new tab).
A mass match supports an identity assignment within the method’s limits. It is not a complete structural description or a substitute for checking the sequence and chemical modifications stated in the material record.
Purity and content are separate
Gross powder can contain water, counterions and other non-peptidic components. Net peptide content and chromatographic purity therefore answer different questions. A separately quantified target amount also needs a method, calibration basis and units. Bachem’s quality-control guide (opens in a new tab) distinguishes these measurements.
- Purity
- The relative composition determined by the stated analytical method.
- Content
- The amount or fraction measured on a defined sample basis.
- Identity
- Evidence supporting the proposed chemical assignment.
Match the report to its record
- Check the exact sample name, identifier, lot and formulation.
- Retain the laboratory, report ID, date, methods and original file.
- Read exclusions, qualifications and missing fields before drawing conclusions.
If identifiers disagree, record the discrepancy. A test date alone does not establish an expiry date, and a historical report should not be relabeled as a current result.